Insertion-type Ultrasonic Flow Meter
- Introduction
- Picture
- Specification
- Download
- Installation Video
- Inquiry
Name:Insertion-type Ultrasonic Flow Meter
Model:LRF-3300SC
Size:254*230*64mm
General Introduction:
LRF-3300S is a fixed type ultrasonic flowmeter which use the transfer time technology.At the same time LRF-3300S has our unique calculate software to ensure the high accuracy and low velocity response. LRF-3300S could add the RTD model and temperature sensor become an energy meter to monitoring the energy use, help to save the energy.It uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant of liquids with small amounts of air bubbles or suspended solids found in most industrial environments. With distinctive features such as high accuracy, high reliability, the MPU in the instrument provides unique digital signal processing and a relevant test programs. This flow meter provides long-term no-drift measurements and sorts the operating software to adjust parameters according to changing conditions.
Selection of parameter:
Model | Transmitter |
LRF-3300S | Ultrasonic flowmeter
Wall mount
Flow range :±0.01m/s ~ ±12m/s
Accuracy :±0.5% of the measure value
Repeatability:0.1% of the measure value
Display:240*128 backlit LCD
Power supply:90-250VAC,48-63Hz or 10-36VDC
Output:4-20Ma,OCT,Relay
Communication :RS232/RS485,Modbus
|
Code | Output |
1 | OCT,Relay,RS232/485,4-20mA |
2 | OCT,Relay,RS232/485,4-20mA,RTD |
Code | Transducer |
TT05 | plug-in, IP68,Operating temperature: -40℉ ~ + 266℉(-40℃ ~ +130℃) |
XXX | Transducer cable length |
030 | Standard length 30ft (9m) |
XXX | Max length to 1000ft (300m) |
Code | Temperature sensor |
PT1000 | PT1000 temperature sensor |
Standard Physical Map:
Transmitter:
Transducer:
weight:
Performance | |
Flow range | ±0.09ft/s ~ ±40ft/s (±0.03m/s ~ ±12m/s) |
Accuracy | ±0.5% of reading (for ±1.5ft/s~±40ft/s) |
Repeatability | 0.1% of measured value |
Pipe size | 1"to 200" (50mm to 5000mm). Pipe size under 1" is an option |
Linearity | ±0.5% |
Function | |
Outputs | Analog output: 4~20mA, max load 750 Ω.
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is
adjustable)
Relay output: SPST, max 1Hz,(1A@125VAC or 2A@30VDC)
|
Communication | RS232 & RS485 |
Memory | TF card (Max 32G) |
Power supply | 90 to 245 VAC, 48 to 63 Hz. Or 10 to 36VDC |
Display | 240*128 back lit LCD |
Temperature | Transmitter: -40℉~ 140℉(- 40℃ ~ 60℃ ).
Transducer: -40℉~ 266 ℉(- 40 ℃ ~ 130 ℃ )
|
Humidity | Up to 99% RH,non-condensing |
physical | |
Transmitter | IP65 |
Transducer | IP68
Encapsulated design
Double-shielded transducer cable
Standard/maximum cable length:30ft/1000ft(9m/300m)
|